Doctors' exposure to ionising radiation may be cause for concern
EDITORConcerns about patients' exposure to radiation at the hands of their doctors should extend to health professionals.1 Orthopaedic theatre staff may be unaware of the following simple facts:
- Lead gowns should be 0.35 mm thick
- Surgeons' exposure is reduced by the inverted C-arm (image intensifier) technique2
- Any distance < 90 cm from the C-arm is unsafe3
- The thyroid gland should be protected at all times4
- Hands are at high risk from radiation and orthopaedic surgeons controlling the image intensifier can reduce hand exposure.5
In addition to the Ionising Radiation (Medical Exposure) Regulations 2000 (www.doh.gov.uk/irmer.htm), all orthopaedic theatre staff should be monitored for central and peripheral exposure to radiation. Lead gowns should be regularly checked for cracks and thickness, and the image intensifier for radiation scattering. A study of all radiation related head and neck and upper limb malignancies would, no doubt, be of great interest to the British Orthopaedic Association.
Eleftherios Tsiridis, consultant orthopaedic surgeon
etsiridis{at}hotmail.com
Patrick J Lusty, specialist registrar in trauma and orthopaedics, North East Thames Rotation,
Ali A Narvani, specialist registrar in trauma and orthopaedics, North West Thames Rotation
Whittington Hospital, London N19 5NF
Eva M Tsapakis, clinical research fellow
King's College Hospital, London SE5 8AF
Competing interests: None declared.
References
- Shiralkar S, Rennie A, Snow M, Galland RB, Lewis MH, Gower-Thomas K. Doctors' knowledge of radiation exposure: questionnaire study. BMJ
2003;327: 371-2. (16 August.)[Free Full Text]
- Tremains MR, Georgiadis GM, Dennis MJ. Radiation exposure with use of the inverted-c-arm technique in upper-extremity surgery. J Bone Joint Surg Am
2001;83-A: 674-8.[Abstract/Free Full Text]
- Mehlman CT, DiPasquale TG. Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?". J Orthop Trauma
1997;11: 392-8.[CrossRef][ISI][Medline]
- Tse V, Lising J, Khadra M, Chiam Q, Nugent R, Yeaman L, Mulcahy M. Radiation exposure during fluoroscopy: should we be protecting our thyroids? Aust N Z J Surg
1999;69: 847-8.[Medline]
- Noordeen MH, Shergill N, Twyman RS, Cobb JP, Briggs T. Hazard of ionizing radiation to trauma surgeons: reducing the risk. Injury
1993;24: 562-4.[CrossRef][ISI][Medline]

CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
Relevant Article
-
Doctors' knowledge of radiation exposure: questionnaire study
- S Shiralkar, A Rennie, M Snow, R B Galland, M H Lewis, and K Gower-Thomas
BMJ 2003 327: 371-372.
[Full Text]
[PDF]